Dental drill stand from MEISINGER - sterilisable in anodised aluminium
MEISINGER Bur Blocks for effective handling of dental drills
MEISINGER bur blocks for rotary instruments are perfect for our rotary instruments and ensure effective and safe handling of dental instruments in practices and laboratories in terms of cleaning, sterilisation and organisation.
The advantages of MEISINGER drill stands at a glance:
- Sterilisation with moist heat in an autoclave (e.g. at 134 °C / 273 °F)
- Opening on the long side for optimum sterilisation
- Latching device on the side to prevent accidental opening of the protective lid
- ideally suited for the shaft types specified on the drill stands
- for cleaning solutions with a PH value of 5.5-8.5
Filter
Tip
Burblock FG+RA H31, OR402GEL
For 21 contra-angle handpieces (204) and 21 FG instruments (314)
approx. W 63 x H 31 x D 25 mm
Note: These products are made of coloured anodised aluminium. The use of some chemical cleaning solutions can slightly discolour the products. Therefore, do not use cleaning solutions that are too alkaline or too acidic (recommended pH value 5.5-8.5). The following sterilisation method can be used without hesitation: Sterilisation with moist heat in an autoclave (e.g. at 134 °C / 273 °F). When sterilising, please be sure to observe the operating instructions of the device manufacturer and the instructions regarding the sterilisation time. The drill stands are only optimally suited for instruments with the specified shank types. Instruments with shorter shafts are not adequately secured and may fall out.
Quantity per package: 1
Burblock for 10 FG + 10 RA, OR638
For 10 contra-angle handpieces (204, 205) and 10 FG instruments (314, 315, 316).
Note: These products are made of coloured anodised aluminium. The use of some chemical cleaning solutions can slightly discolour the products. Therefore, do not use cleaning solutions that are too alkaline or too acidic (recommended pH value 5.5-8.5). The following sterilisation method can be used without hesitation: Sterilisation with moist heat in an autoclave (e.g. at 134 °C / 273 °F). When sterilising, please be sure to observe the operating instructions of the device manufacturer and the instructions regarding the sterilisation time. The drill stands are only optimally suited for instruments with the specified shank types. Instruments with shorter shafts are not adequately secured and may fall out.
Quantity per package: 1
Burblock for 10 FG + 5 RA, OR100
For 5 contra-angle handpieces (205) and 10 FG instruments (316, 317).
Note: These products are made of coloured anodised aluminium. The use of some chemical cleaning solutions can slightly discolour the products. Therefore, do not use cleaning solutions that are too alkaline or too acidic (recommended pH value 5.5-8.5). The following sterilisation method can be used without hesitation: Sterilisation with moist heat in an autoclave (e.g. at 134 °C / 273 °F). When sterilising, please be sure to observe the operating instructions of the device manufacturer and the instructions regarding the sterilisation time. The drill stands are only optimally suited for instruments with the specified shank types. Instruments with shorter shafts are not adequately secured and may fall out.
Quantity per package: 1
Burblock for 12 FG + 6 RA, OR603
For 6 contra-angle handpieces (204, 205) and 12 FG instruments (314, 315, 316).
Note: These products are made of coloured anodised aluminium. The use of some chemical cleaning solutions can slightly discolour the products. Therefore, do not use cleaning solutions that are too alkaline or too acidic (recommended pH value 5.5-8.5). The following sterilisation method can be used without hesitation: Sterilisation with moist heat in an autoclave (e.g. at 134 °C / 273 °F). When sterilising, please be sure to observe the operating instructions of the device manufacturer and the instructions regarding the sterilisation time. The drill stands are only optimally suited for instruments with the specified shank types. Instruments with shorter shafts are not adequately secured and may fall out.
Quantity per package: 1
Burblock for 12 RA, OR622
Note: These products are made of coloured anodised aluminium. The use of some chemical cleaning solutions can slightly discolour the products. Therefore, do not use cleaning solutions that are too alkaline or too acidic (recommended pH value 5.5-8.5). The following sterilisation method can be used without hesitation: Sterilisation with moist heat in an autoclave (e.g. at 134 °C / 273 °F). When sterilising, please be sure to observe the operating instructions of the device manufacturer and the instructions regarding the sterilisation time. The drill stands are only optimally suited for instruments with the specified shank types. Instruments with shorter shafts are not adequately secured and may fall out.
Quantity per package: 1
Burblock for 14 FG + 7 RA, GR102
For 7 contra-angle handpieces (204, 205) and 14 FG instruments (314, 315, 316).
Note: These products are made of coloured anodised aluminium. The use of some chemical cleaning solutions can slightly discolour the products. Therefore, do not use cleaning solutions that are too alkaline or too acidic (recommended pH value 5.5-8.5). The following sterilisation method can be used without hesitation: Sterilisation with moist heat in an autoclave (e.g. at 134 °C / 273 °F). When sterilising, please be sure to observe the operating instructions of the device manufacturer and the instructions regarding the sterilisation time. The drill stands are only optimally suited for instruments with the specified shank types. Instruments with shorter shafts are not adequately secured and may fall out.
Quantity per package: 1
Burblock for 14 FG + 7 RA, OR102
For 7 contra-angle handpieces (204, 205) and 14 FG instruments (314, 315, 316).
Note: These products are made of coloured anodised aluminium. The use of some chemical cleaning solutions can slightly discolour the products. Therefore, do not use cleaning solutions that are too alkaline or too acidic (recommended pH value 5.5-8.5). The following sterilisation method can be used without hesitation: Sterilisation with moist heat in an autoclave (e.g. at 134 °C / 273 °F). When sterilising, please be sure to observe the operating instructions of the device manufacturer and the instructions regarding the sterilisation time. The drill stands are only optimally suited for instruments with the specified shank types. Instruments with shorter shafts are not adequately secured and may fall out.
Quantity per package: 1
Burblock for 15 FG, BL300
Note: These products are made of coloured anodised aluminium. The use of some chemical cleaning solutions can slightly discolour the products. Therefore, do not use cleaning solutions that are too alkaline or too acidic (recommended pH value 5.5-8.5). The following sterilisation method can be used without hesitation: Sterilisation with moist heat in an autoclave (e.g. at 134 °C / 273 °F). When sterilising, please be sure to observe the operating instructions of the device manufacturer and the instructions regarding the sterilisation time. The drill stands are only optimally suited for instruments with the specified shank types. Instruments with shorter shafts are not adequately secured and may fall out.
Quantity per package: 1
Burblock for 15 FG, GR300
For 15 FG instruments (314, 315, 316).
Note: These products are made of coloured anodised aluminium. The use of some chemical cleaning solutions can slightly discolour the products. Therefore, do not use cleaning solutions that are too alkaline or too acidic (recommended pH value 5.5-8.5). The following sterilisation method can be used without hesitation: Sterilisation with moist heat in an autoclave (e.g. at 134 °C / 273 °F). When sterilising, please be sure to observe the operating instructions of the device manufacturer and the instructions regarding the sterilisation time. The drill stands are only optimally suited for instruments with the specified shank types. Instruments with shorter shafts are not adequately secured and may fall out.
Quantity per package: 1
Burblock for 15 FG, OR300
For 15 FG instruments (314, 315, 316).
Note: These products are made of coloured anodised aluminium. The use of some chemical cleaning solutions can slightly discolour the products. Therefore, do not use cleaning solutions that are too alkaline or too acidic (recommended pH value 5.5-8.5). The following sterilisation method can be used without hesitation: Sterilisation with moist heat in an autoclave (e.g. at 134 °C / 273 °F). When sterilising, please be sure to observe the operating instructions of the device manufacturer and the instructions regarding the sterilisation time. The drill stands are only optimally suited for instruments with the specified shank types. Instruments with shorter shafts are not adequately secured and may fall out.
Quantity per package: 1
Burblock for 15 HP, BL700
For 15 handpiece instruments (104, 105).
Note: These products are made of coloured anodised aluminium. The use of some chemical cleaning solutions can slightly discolour the products. Therefore, do not use cleaning solutions that are too alkaline or too acidic (recommended pH value 5.5-8.5). The following sterilisation method can be used without hesitation: Sterilisation with moist heat in an autoclave (e.g. at 134 °C / 273 °F). When sterilising, please be sure to observe the operating instructions of the device manufacturer and the instructions regarding the sterilisation time. The drill stands are only optimally suited for instruments with the specified shank types. Instruments with shorter shafts are not adequately secured and may fall out.
Quantity per package: 1
Burblock for 15 HP, GR700
Note: These products are made of coloured anodised aluminium. The use of some chemical cleaning solutions can slightly discolour the products. Therefore, do not use cleaning solutions that are too alkaline or too acidic (recommended pH value 5.5-8.5). The following sterilisation method can be used without hesitation: Sterilisation with moist heat in an autoclave (e.g. at 134 °C / 273 °F). When sterilising, please be sure to observe the operating instructions of the device manufacturer and the instructions regarding the sterilisation time. The drill stands are only optimally suited for instruments with the specified shank types. Instruments with shorter shafts are not adequately secured and may fall out.
Quantity per package: 1
Burblock for 15 HP, OR700
For 15 handpiece instruments (104, 105).
Note: These products are made of coloured anodised aluminium. The use of some chemical cleaning solutions can slightly discolour the products. Therefore, do not use cleaning solutions that are too alkaline or too acidic (recommended pH value 5.5-8.5). The following sterilisation method can be used without hesitation: Sterilisation with moist heat in an autoclave (e.g. at 134 °C / 273 °F). When sterilising, please be sure to observe the operating instructions of the device manufacturer and the instructions regarding the sterilisation time. The drill stands are only optimally suited for instruments with the specified shank types. Instruments with shorter shafts are not adequately secured and may fall out.
Quantity per package: 1
Burblock for 15 RA, GR202
For 15 contra-angle handpiece instruments (205).
Note: These products are made of coloured anodised aluminium. The use of some chemical cleaning solutions can slightly discolour the products. Therefore, do not use cleaning solutions that are too alkaline or too acidic (recommended pH value 5.5-8.5). The following sterilisation method can be used without hesitation: Sterilisation with moist heat in an autoclave (e.g. at 134 °C / 273 °F). When sterilising, please be sure to observe the operating instructions of the device manufacturer and the instructions regarding the sterilisation time. The drill stands are only optimally suited for instruments with the specified shank types. Instruments with shorter shafts are not adequately secured and may fall out.
Quantity per package: 1
Burblock for 15 RA, OR202
For 15 contra-angle handpiece instruments (205).
Note: These products are made of coloured anodised aluminium. The use of some chemical cleaning solutions can slightly discolour the products. Therefore, do not use cleaning solutions that are too alkaline or too acidic (recommended pH value 5.5-8.5). The following sterilisation method can be used without hesitation: Sterilisation with moist heat in an autoclave (e.g. at 134 °C / 273 °F). When sterilising, please be sure to observe the operating instructions of the device manufacturer and the instructions regarding the sterilisation time. The drill stands are only optimally suited for instruments with the specified shank types. Instruments with shorter shafts are not adequately secured and may fall out.
Quantity per package: 1
Burblock for 20 FG, OR630
Note: These products are made of coloured anodised aluminium. The use of some chemical cleaning solutions can slightly discolour the products. Therefore, do not use cleaning solutions that are too alkaline or too acidic (recommended pH value 5.5-8.5). The following sterilisation method can be used without hesitation: Sterilisation with moist heat in an autoclave (e.g. at 134 °C / 273 °F). When sterilising, please be sure to observe the operating instructions of the device manufacturer and the instructions regarding the sterilisation time. The drill stands are only optimally suited for instruments with the specified shank types. Instruments with shorter shafts are not adequately secured and may fall out.
Quantity per package: 1
Burblock for 20 HP, BS170
For 20 contra-angle handpieces or 20 FG instruments or 20 handpiece instruments.
Quantity per package: 1
Burblock for 20 RA/FG, BS140
For 20 contra-angle handpieces or 20 FG instruments.
Quantity per package: 1